Code Learning:
 
Note:  To activate "Learning Mode", power to the AMLOK relay(s) must be turned off then turned on.
 
A)  When the power is turned on, within 5 seconds, press 'LOCK' and 'UNLOCK' buttons at the same time.  The system will then enter the code learning mode.  The UNLOCK OUTPUT will trigger to remind you that the system is in code learning mode.
 
B)  Within 5 seconds after entering the code learning mode, press any button on the transmitter.  The UNLOCK OUTPUT will trigger to tell you the transmitter has been recognized and is compatible with the system.  A maximum of 12 transmitters can be coded per system.
 
C)  During code learning, if there is no action after 5 seconds, the system will exit the code learning mode.  The UNLOCK OUTPUT will be the reminder.
 
 
Input signals:  Default Negative - See Figure B
 
A)  #3 will input LOCK NEGATIVE/POSITIVE SIGNAL
B)  #2 will input UNLOCK NEGATIVE/POSITIVE SIGNAL
 
 
Configuration Instructions:
The signals input can be changed from default negative to positive.  The outer shell must be removed.  Do this with the RC35a unplugged as shown below by removing the 2 prong jumper switch shown as Figure A in RED.
 
  • FIGURE A
     AMLOK Figure A
  • FIGURE B
    AMLOK Figure B

  • FIGURE C
    AMLOK Figure C
 
 
If you have any questions, comments or concerns regarding the content of this document please call your local AMDOR representative or our customer service department at 1-877-462-6367.

How can we help you?

Contact us for a no obligation discussion about the best product to suit your requirements.
Our friendly and knowledgeable staff are available to help you choose the right product for your needs, or alternatively, provide a quote for our products.

REQUEST QUOTE   CONTACT US
  • Fire Apparatus Manufacturers Association
  • Halton Down Syndrome Association
  • United Way Halton Hamilton
  • Community Living Burlington
  • Innovators Alliance Member
Fire Apparatus Manufacturers Association Halton Down Syndrome Association United Way Halton Hamilton Community Living Burlington Innovators Alliance Member

CONTACT US

3435 South Service Road
Burlington, ON L7N 3W6

AMDOR Inc
4304 Walden Ave.
Lancaster, NY 14086

Toll Free: 877-845-3816
Phone: 905-333-6745

SEND A MESSAGE

CONTACT US

3435 South Service Road
Burlington, ON L7N 3W6

AMDOR Inc
4304 Walden Ave.
Lancaster, NY 14086

Toll Free: 877-845-3816
Phone: 905-333-6745

SEND A MESSAGE

AMDOR

WHITING CANADA

INNOMOTIVE SOLUTIONS GROUP

FMI

truck roll-up door